Skip to content
YuanGan Technology

Solutions

Industry application cases

Six drinking-water scenarios adapted from YuanGan’s official application cases — sensors and analyzers where safety decisions happen.

01

Potable Raw Water

Raw-water plant, on-site installation
Raw-water plant, on-site installation

Early-warning monitoring for rivers, lakes, and reservoirs — turbidity, TSS, pH/ORP, and disinfectant readiness before the plant process train.

Typical parameters

  • Turbidity (mid/high)
  • TSS
  • pH
  • ORP
Discuss this application

Operational challenges

  • Algae blooms, sediment surges, and sudden pollution events at surface sources
  • Need for early warning before treatment trains are overloaded
  • Variable mid/high-range turbidity and suspended solids

Integrated monitoring approach

  • ✓Mid/high-range turbidity and TSS continuous tracking
  • ✓pH and ORP for source-water character shifts
  • ✓SCADA-ready Modbus digital sensors for plant inlet
  • ✓Fits municipal and rural source-water intake stations

02

Treated / Finished Water

Treated-water plant, on-site installation
Treated-water plant, on-site installation

Plant outlet monitoring for ultra-low turbidity, residual chlorine / ClO₂ / O₃, pH, and conductivity — continuous verification for drinking-water compliance.

Typical parameters

  • Ultra-low turbidity
  • Free chlorine / ClO₂ / O₃
  • pH
  • Conductivity
Discuss this application

Operational challenges

  • Tight finished-water turbidity and residual control
  • Disinfection byproduct and residual balance
  • 24/7 compliance reporting for utilities and EPCs

Integrated monitoring approach

  • ✓Ultra-low turbidity (polish / outlet duty)
  • ✓Free chlorine, ClO₂, and ozone residual options
  • ✓pH and conductivity for finished-water quality
  • ✓Analyzer and multi-parameter station form factors

03

Secondary Water Supply

Secondary-supply booster pump room, on-site installation
Secondary-supply booster pump room, on-site installation

Booster stations, tanks, and pressurized networks — catch chlorine decay, turbidity spikes, and sediment risk before water reaches buildings.

Typical parameters

  • Turbidity
  • Residual chlorine / ClO₂
  • pH
  • Temperature
Discuss this application

Operational challenges

  • Bacterial growth risk in tanks and pipes
  • Chlorine decay across pressurized distribution
  • Turbidity fluctuations and sediment accumulation

Integrated monitoring approach

  • ✓Turbidity + residual chlorine / ClO₂ packages
  • ✓Compact analyzers for constrained pump rooms
  • ✓Pressure-friendly flow cells for pipeline taps
  • ✓Cloud or SCADA alarms for decay and spike events

04

Swimming Pools & Leisure

Swimming pool, on-site installation
Swimming pool, on-site installation

Free chlorine, pH, ORP, and turbidity packages for competition, hotel, campus, and fitness pools — stable recirculation control with OEM branding options.

Typical parameters

  • Free chlorine
  • ORP
  • pH
  • Turbidity
Discuss this application

Operational challenges

  • Balancing disinfectant residual, pH, and turbidity
  • Pathogen control without over-dosing discomfort
  • Audit trails for health inspections

Integrated monitoring approach

  • ✓Free chlorine / ORP / pH continuous loops
  • ✓Reagent-free residual sensor options
  • ✓Integrator-ready kits for pool system houses
  • ✓Private-label path for leisure OEMs

05

Piped Direct Drinking Water

Piped direct-drinking water, on-site installation
Piped direct-drinking water, on-site installation

UF / RO community, campus, and building systems — verify polish-stage quality, membrane integrity signals, and taste-critical TDS / DO points.

Typical parameters

  • Low-range turbidity
  • TDS / conductivity
  • DO
  • Residual disinfectant
Discuss this application

Operational challenges

  • Recontamination risk after UF/RO polish
  • Membrane integrity and taste-critical TDS control
  • Multi-building fleets needing consistent instruments

Integrated monitoring approach

  • ✓Low-range turbidity and conductivity / TDS
  • ✓Residual disinfectant where required by the scheme
  • ✓Multi-parameter kits for facility teams
  • ✓OEM branding for direct-drinking system suppliers

06

Medical & Specialty Wastewater

Disinfection residual and process monitoring for hospital disinfection wastewater and specialty water processes — verify treatment efficacy with digital sensors.

Typical parameters

  • Disinfectant residual
  • pH / ORP
  • Turbidity
Discuss this application

Operational challenges

  • Pathogen-laden and chemically complex wastewater
  • Need to verify disinfection efficacy before discharge
  • Harsh sample points that punish fragile instruments

Integrated monitoring approach

  • ✓Disinfectant residual verification (chlorine / ClO₂ / O₃)
  • ✓Digital sensors for integrator panels
  • ✓Protocol-friendly outputs for hospital BMS / SCADA
  • ✓Support for specialty process water edges

Building a package for a utility or EPC bid?

Tell us your parameters, application, and volume — our export team responds by email or WhatsApp.

yan@yuangankeji.com · +86-400-1688-667 · WhatsApp +86 151 7883 0466